{"id":954,"date":"2010-12-15T23:30:13","date_gmt":"2010-12-16T06:30:13","guid":{"rendered":"http:\/\/www.themoehrings.com\/?p=954"},"modified":"2026-03-03T09:24:09","modified_gmt":"2026-03-03T15:24:09","slug":"labview-exceptions-a-paradigm-shift-to-error-handling-in-labview","status":"publish","type":"post","link":"https:\/\/www.themoehrings.com\/index.php\/2010\/12\/labview-exceptions-a-paradigm-shift-to-error-handling-in-labview","title":{"rendered":"LabVIEW Exceptions: a paradigm shift to error handling in LabVIEW"},"content":{"rendered":"<p>This is a presentation I gave to about 40 <a title=\"CLA\" href=\"https:\/\/learn.ni.com\/pages\/certified-labview-architect\" target=\"_blank\" rel=\"noopener\">Certified LabVIEW Architects<\/a> back in March 2010\u00a0at the\u00a0CLA Summit in Austin, TX.\u00a0 It presents some ideas on ways in which exception handling error techniques that are used in C++ and Java could be incorporated into LabVIEW by National Instruments, and the benefits of these techniques over the error handling techniques currently supported by LabVIEW.\u00a0 The general feedback I got from talking with people after the presentation was that it was very insightful but would require years of development and test within National Instruments and then years more before the user community would begin to adopt it.\u00a0 Therefore, National Instruments has to seriously question the Return on Investment of such an enhancement.\u00a0 Is this a feature request that is likely to generate profit?\u00a0 Probably not in this decade, I&#8217;ll admit to that.\u00a0 But I think in the long run, I think graphical programming is going to <em>need<\/em> to incorporate something like this to be considered a serious contender to traditional text based languages.<\/p>\n<p><a href=\"https:\/\/www.themoehrings.com\/wp-content\/uploads\/2010\/12\/LabVIEW-Exceptions.pdf\">LabVIEW Exceptions<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>This is a presentation I gave to about 40 Certified LabVIEW Architects back in March 2010\u00a0at the\u00a0CLA Summit in Austin, TX.\u00a0 It presents some ideas on ways in which exception handling error techniques that are used in C++ and Java could be incorporated into LabVIEW by National Instruments, and the benefits of these techniques over&#8230;<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[15],"tags":[],"class_list":["post-954","post","type-post","status-publish","format-standard","hentry","category-labview","wpcat-15-id"],"jetpack_publicize_connections":[],"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p504YJ-fo","jetpack-related-posts":[{"id":1896,"url":"https:\/\/www.themoehrings.com\/index.php\/2012\/03\/separating-user-interface-from-implementation-in-labview","url_meta":{"origin":954,"position":0},"title":"Separating User Interface from Implementation in LabVIEW","author":"Nate","date":"March 18, 2012","format":false,"excerpt":"I had the opportunity to give the opening presentation at the 2012 Certified LabVIEW Architect on March 5th. \u00a0An expanded title \u00a0would be \"A Survey of Tools and Techniques for Separating the User Interface from Business Logic Implementation in LabVIEW\", but that doesn't fit on a slide very well. The\u2026","rel":"","context":"In &quot;LabVIEW&quot;","block_context":{"text":"LabVIEW","link":"https:\/\/www.themoehrings.com\/index.php\/cat\/labview"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":1684,"url":"https:\/\/www.themoehrings.com\/index.php\/2011\/10\/accessing-objects-by-reference-in-labvoop","url_meta":{"origin":954,"position":1},"title":"Accessing Objects By Reference in LabVOOP","author":"Nate","date":"October 24, 2011","format":false,"excerpt":"https:\/\/decibel.ni.c...\/docs\/DOC-18320 Motivation for this presentation: At the 2011 CLA Summit, National Instruments asked us what we thought was missing from LabVIEW or what needed to be improved. I already knew NI\u2019s position on this, but my feedback to NI and direct conversation with Stephen Mercer, father of LabVOOP, was that\u2026","rel":"","context":"In &quot;LabVIEW&quot;","block_context":{"text":"LabVIEW","link":"https:\/\/www.themoehrings.com\/index.php\/cat\/labview"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":10578,"url":"https:\/\/www.themoehrings.com\/index.php\/2018\/03\/unit-testing-in-labview","url_meta":{"origin":954,"position":2},"title":"Unit Testing in LabVIEW","author":"Nate","date":"March 4, 2018","format":false,"excerpt":"Attached are the slides and example project presented by Nate Moehring during the March 1st, 2018 presentation at the LabVIEW Architect Forum on advanced tips and tricks for writing unit tests in LabVIEW.\u00a0 Some justification is provided for unit testing in general, but most of the presentation covers the advanced\u2026","rel":"","context":"In &quot;LabVIEW&quot;","block_context":{"text":"LabVIEW","link":"https:\/\/www.themoehrings.com\/index.php\/cat\/labview"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":951,"url":"https:\/\/www.themoehrings.com\/index.php\/2010\/12\/new-blog-category-labview","url_meta":{"origin":954,"position":3},"title":"New blog category: LabVIEW","author":"Nate","date":"December 15, 2010","format":false,"excerpt":"Future of LabVIEW","rel":"","context":"In &quot;LabVIEW&quot;","block_context":{"text":"LabVIEW","link":"https:\/\/www.themoehrings.com\/index.php\/cat\/labview"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.themoehrings.com\/wp-content\/uploads\/2010\/12\/68a47da47f1a03454aa98e84b3420c5f.jpeg?fit=800%2C200&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.themoehrings.com\/wp-content\/uploads\/2010\/12\/68a47da47f1a03454aa98e84b3420c5f.jpeg?fit=800%2C200&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/www.themoehrings.com\/wp-content\/uploads\/2010\/12\/68a47da47f1a03454aa98e84b3420c5f.jpeg?fit=800%2C200&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/www.themoehrings.com\/wp-content\/uploads\/2010\/12\/68a47da47f1a03454aa98e84b3420c5f.jpeg?fit=800%2C200&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":10582,"url":"https:\/\/www.themoehrings.com\/index.php\/2018\/03\/labview-tortoise-or-hare","url_meta":{"origin":954,"position":4},"title":"LabVIEW &#8211; Tortoise or Hare","author":"Nate","date":"March 4, 2018","format":false,"excerpt":"Attached are the slides presented by Nate Moehring on Sept 19th, 2017 at the Certified LabVIEW Architect Summit on best practices for managing performance risks associated with LabVIEW applications that handle large amounts of data, as well as advanced tips and tricks for writing high performance LabVIEW code. LabVIEW -\u2026","rel":"","context":"In &quot;LabVIEW&quot;","block_context":{"text":"LabVIEW","link":"https:\/\/www.themoehrings.com\/index.php\/cat\/labview"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":2719,"url":"https:\/\/www.themoehrings.com\/index.php\/2013\/04\/religious-about-labview","url_meta":{"origin":954,"position":5},"title":"Religious about LabVIEW","author":"Nate","date":"April 5, 2013","format":false,"excerpt":"I realized this week at the CLA Summit that I am religious about LabVIEW. What does this mean? It means that despite conflicting evidence and statements made by individuals about the strengths and weaknesses of LabVIEW (including key individuals within NI), I have made a choice long ago to have\u2026","rel":"","context":"In &quot;LabVIEW&quot;","block_context":{"text":"LabVIEW","link":"https:\/\/www.themoehrings.com\/index.php\/cat\/labview"},"img":{"alt_text":"CLA Logo","src":"https:\/\/i0.wp.com\/www.themoehrings.com\/wp-content\/uploads\/2010\/09\/LabVIEW_Cert_Arch-4c-300x81.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]}],"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.themoehrings.com\/index.php\/wp-json\/wp\/v2\/posts\/954","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.themoehrings.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.themoehrings.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.themoehrings.com\/index.php\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.themoehrings.com\/index.php\/wp-json\/wp\/v2\/comments?post=954"}],"version-history":[{"count":4,"href":"https:\/\/www.themoehrings.com\/index.php\/wp-json\/wp\/v2\/posts\/954\/revisions"}],"predecessor-version":[{"id":36403,"href":"https:\/\/www.themoehrings.com\/index.php\/wp-json\/wp\/v2\/posts\/954\/revisions\/36403"}],"wp:attachment":[{"href":"https:\/\/www.themoehrings.com\/index.php\/wp-json\/wp\/v2\/media?parent=954"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.themoehrings.com\/index.php\/wp-json\/wp\/v2\/categories?post=954"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.themoehrings.com\/index.php\/wp-json\/wp\/v2\/tags?post=954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}